Send Message
Home ProductsUltrasonic Flaw Detector

Ultrasonic Full Wave Ndt Flaw Detector 10 Detection Channel

Certification
China HUATEC  GROUP  CORPORATION certification
China HUATEC  GROUP  CORPORATION certification
Customer Reviews
wide range of NDT products, we can get all in huatec group. We prefer to buy from them. Rudolf Shteinman Russia

—— Rudolf Shteinman

I like the service, very quick response, professional work. Aret Turkey

—— Aret Kaya

huatec hardness tester, very good quality,we are very satisfied with the portable hardness tester RHL-50. Kumaren Govender Sotuth Africa

—— Kumaren Govender

I'm Online Chat Now

Ultrasonic Full Wave Ndt Flaw Detector 10 Detection Channel

Ultrasonic Full Wave Ndt Flaw Detector 10 Detection Channel
Ultrasonic Full Wave Ndt Flaw Detector 10 Detection Channel

Large Image :  Ultrasonic Full Wave Ndt Flaw Detector 10 Detection Channel

Product Details:
Place of Origin: China
Brand Name: HUATEC
Certification: ISO, CE, GOST
Model Number: FD-600
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard export package
Delivery Time: 1-4working days
Payment Terms: T/T, Western Union,Paypal
Supply Ability: 500Pcs

Ultrasonic Full Wave Ndt Flaw Detector 10 Detection Channel

Description
Waveform Displaying Way: Full Wave Dynamic Range: ≥32 DB
Suppress: 0%~80% Of Screen Height, Step: 1% Detection Channel: 10
P-delay (us): P-delay:0.0~99.99 Adjusting Steps: 0.01 D-delay (us): D-delay (us):-20~+3400
Range Of Scanning (mm): Range Of Scanning (mm):0~10000 MTLVEL(m/s): MTLVEL:1000~9999
High Light:

full wave ndt flaw detector

,

10 channel ndt flaw detector

,

10 channel ultrasonic flaw detector

High quality and high performance Various new functions ultrasonic flaw detector FD-600

 

Performance Features

1.Measurement displaying mode: type A displaying mode

2.It is provided with linear reject function, the highest reject is 80% of the screen height;

3.switch over arbitrarily among three detecting modes: single-probe , dual-probe ones and through transmission;

4.It has gate setting and alarming function. Can set the position and width of gate freely on the screen, and can set alarm for forbidden wave and loss wave respectively;

5.500 detecting channels are available with a separate detecting parameter and DAC curve in every channel.

6.500 A scanned images, parameters and DAC curves can be stored in

7.Two input methods, angles and K value.

8.Auto-gain

9.Automatic generation of DAC curve by standard test block, 30 points can be 10.recorded at most, three adjustable bias curves are generated with the function of Correction.

11.Automatic generation of AVG curve by three type of flaw

12.Make test videos and Auto playback

13.Auto shutdown mode to save power ;

14.Can playback the saved images, call out the saved A-scan images from

Equipped with delete function, with which any data can be deleted from storage zone;

15. Two measuring unit: mm/inch;

16. Real-time clock;

17.Auto-calibration of probe.

18.Memory of peaks.

19.Can freeze and defreeze waveform and detection parameters;

20. Can lock/unlock the system parameters;

21.Measuring of sound path and analyze of echo times;

22. Can indicate power state in real time;

23. RS232 communication port available;

24. Having buzzer prompt during operation;

25. Compact, light and easy to operate.

 

 

Designation Technical Data
Range of scanning (mm) Range of scanning (mm):0~10000
D-delay (ms) D-delay (ms):-20~+3400
P-delay (ms)

P-delay:0.0~99.99

Adjusting steps: 0.01

MTLVEL(m/s)

MTLVEL:1000~9999

7 fixed levels: 2260,2730,3080,3230,4700,5920,6300

Adjusting steps: 1

Working mode Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission (transmission probe)
Frequency of repeating transmitting (MHz) 0.4–20
Gain adjustment (dB)

0~110

Adjusting step: 0.0,0.2,0.5,1,2,6,12

Suppress 0%~80% of screen height, step: 1%
Vertical linear error Vertical linear error is not more than 3%
Horizontal linear error Not more than 0.2% in the scanning range
Allowance of detection sensitivity ≥62 dB
Dynamic range ≥32 dB
Alarm Three modes, i.e. forbidden wave, loss wave and auto
Display Display: high-brightness graphic lattice
A-Scan display area A-Scan display freezing and de-freezing A-Scan filling
Waveform displaying way full wave
Detection channel 10
Data save 500 A-Scan images (including setting of instrument)
Standard communication interface with PC RS232
Measuring unit mm/inch
Battery Li battery 4×3.6V 5000mAh
Power adaptor

Input 100V~240V/50Hz~60Hz

Output 9V~12VDC/3A~4A

Working temperature 0℃~40℃
Working humidity 20%~90%
Port type BNC
Overall dimension (mm) 210×150×45
Weight (kg) 1.0

 

Standard configuration   Spare parts

1. Host 1

2. One straight probe

3. One oblique probe

4. One test block

5. Two probe lines

6. Power adapter 1

7. Two lithium batteries

8. Seat Charging Unit 1

9. SD Storage Card

10. Reader 1

11. 1 manual

12. One copy of certificate, warranty card and packing card

  Instrument bags, straps, belts

 

Conatact Person:

High quality and high performance Various new functions ultrasonic flaw detector FD-600 High quality and high performance Various new functions ultrasonic flaw detector FD-600

Esther Yu Scan here for my name card

Mobile Phone: 0086-13910983110
Whatsapp: +86 18846112524
Skype: cindydon
Address : 7th Floor, Chengyuan Building B, the Mid. Road of Jiancaicheng Haidian Dist.BeiJing,CHINA 100096
Worktime : 9:00-18:00(Beijing time)
Business Phone: 86-10-82921131(Working time) 86-13910983110(Nonworking time)
Fax : 86-10-82916893

Contact Details
HUATEC GROUP CORPORATION

Contact Person: Ms. Shifen Yuan

Tel: 8610 82921131,8613910983110

Fax: 86-10-82916893

Send your inquiry directly to us (0 / 3000)