HUATEC GROUP CORPORATION

Professional Non Destructive Testing Equipment

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsNon Destructive Testing Equipment

penetrant calibration block test block PT test specimen developer,remover

Good quality Ultrasonic Flaw Detector for sales
Good quality Ultrasonic Flaw Detector for sales
wide range of NDT products, we can get all in huatec group. We prefer to buy from them. Rudolf Shteinman Russia

—— Rudolf Shteinman

I like the service, very quick response, professional work. Aret Turkey

—— Aret Kaya

huatec hardness tester, very good quality,we are very satisfied with the portable hardness tester RHL-50. Kumaren Govender Sotuth Africa

—— Kumaren Govender

I'm Online Chat Now

penetrant calibration block test block PT test specimen developer,remover

China penetrant calibration block test block PT test specimen developer,remover supplier
penetrant calibration block test block PT test specimen developer,remover supplier penetrant calibration block test block PT test specimen developer,remover supplier penetrant calibration block test block PT test specimen developer,remover supplier penetrant calibration block test block PT test specimen developer,remover supplier

Large Image :  penetrant calibration block test block PT test specimen developer,remover

Product Details:

Place of Origin: Beijing
Brand Name: HUATEC
Certification: ISO
Model Number: YM-A

Payment & Shipping Terms:

Minimum Order Quantity: 1pc
Packaging Details: Carton
Delivery Time: 3 working days
Payment Terms: T/T, Western Union, L/C
Supply Ability: 10000per month
Contact Now
Detailed Product Description
Material: Aluminum

penetrant calibration block test block PT test specimen developer,remover

 

Model:YM-B

All linear dimensions to the requirements of AS2083/2005, BS2704/1978/1983, where applicable. Heat treatment to the requirements of GB/T6394/2002. where practicable tolerances to (+/-0.1mm) unless otherwise stated. Treated to 920 degrees C for 30 minutes, water quenched, 650 degrees C for 3 hours, air cooled

Material standard:according to ISO 10474-3.1.B,JIS G 0415-3.1.B

Depth:100µm

Width target value:0.5µm

Test standard:ISO 3452-3:1998(E),JB/T6064

penetrant calibration block test block PT test specimen developer,remover

 

 

Model:YM-C

All linear dimensions to the requirements of AS2083/2005, BS2704/1978/1983, where applicable. Heat treatment to the requirements of GB/T6394/2002. where practicable tolerances to (+/-0.1mm) unless otherwise stated. Treated to 920 degrees C for 30 minutes, water quenched, 650 degrees C for 3 hours, air cooled

Material standard:according to ISO 10474-3.1.B,JIS G 0415-3.1.B

Depth:100µm

Width target value:0.5µm

Test standard:ISO 3452-3:1998(E),JB/T6064

 

penetrant calibration block test block PT test specimen developer,remover

 

Model:YM-D

All linear dimensions to the requirements of AS2083/2005, BS2704/1978/1983, where applicable. Heat treatment to the requirements of GB/T6394/2002. where practicable tolerances to (+/-0.1mm) unless otherwise stated. Treated to 920 degrees C for 30 minutes, water quenched, 650 degrees C for 3 hours, air cooled

Material standard:according to ISO 10474-3.1.B,JIS G 0415-3.1.B

Depth:150µm

Width target value:0.5µm,1.0μ and 1.5μ

Test standard:ISO 3452-3:1998(E),JB/T6064

 penetrant calibration block test block PT test specimen developer,remover

 

Model: YM-A Aluminum Comparator Block

Through the physical and chemical test type A block material for LY12 aluminum alloy for materials, the chemical components conform to the provisions of ASTM,GB/T3190

By means of a micrometer measurement block length is 76 + 0.1 ㎜, and the width fifty + / - 0.1 ㎜, thick and ± 1 ㎜. Cut along the length center evenly divided into two pieces, and in block A and B and unity Numbers, block length orientation and plate rolling direction. Milling, grinding the surface roughness after treatment for Ra = 1.2 u m - 2.5 u m.

Color: Visual its color is silvery white.

Oxidizing property :In -55 ℃ ~ 200 ℃ - store between three years not metamorphism, no oxidation,

Crack: In the same Numbers of the A and B block with dye penetrant inspection method measured random crack 3 μ m, 3 μ m ~ 5 μ m and more than 5 μ m open crack on one side not less than four, and there are two above width is not more than 3 μ m open crack. Block A and B on the surface crack distribution is similar.

ASTME165 standard

 

Type I Penetrate block

penetrant calibration block test block PT test specimen developer,remover

 

 

Type II Penetrate block

 

 

penetrant calibration block test block PT test specimen developer,removerpenetrant calibration block test block PT test specimen developer,remover

 

Penetrate Block B3

 

 

penetrant calibration block test block PT test specimen developer,remover

 

 

Penetrate Block B5

 

 

penetrant calibration block test block PT test specimen developer,remover

 

Penetrate block PSM-5

penetrant calibration block test block PT test specimen developer,remover

 

Contact Details
HUATEC GROUP CORPORATION

Contact Person: Mr. Davis Chen

Send your inquiry directly to us (0 / 3000)