Product Details:
|
| Range: | 0-1000mm | Gain: | 0-120dB |
|---|---|---|---|
| Curve Offered: | DAC、AVG、TCG、B Scan、AWS | Protection: | IP65,water/oil Proof,dust Proof |
| Noise: | Very Low Noise | ||
| Highlight: | portable ultrasonic flaw detector,digital ultrasonic flaw detector |
||
High Resolution Digtal Ultrasonic Flaw Detector A Scan B Scan FD520 with Automated 0 - 120dB gain
![]()
![]()
![]()
Main faetures:
★ Automated calibration,Automated gain, 0-120dB gain
★ DAC,AVG,TCG,B scan,AWS
★ High-speed capture and very low noise
★ Solid metal housing,water / oil proof,dust proof
★ high contrast viewing of the waveform from bright
★ Powerful pc software and reports can be export to excel
|
Parameter |
Title |
Parameter |
|
|
Measuring Range(mm) |
0 ~ 10000 |
Measurement Mode |
Single,Dual,Thru |
|
Vertical Linearity Error |
≤3% |
Reject |
0~80% |
|
Horizontal Linearity Error |
≤0.1% |
Pulse Displacement(μs) |
-20 ~ +3400 |
|
Sensitivity Leavings |
≥62dB |
Zero(μs) |
0.0 ~ 99.99 |
|
Dynamic range |
≥32dB |
Port Type |
BNC(Q9) |
|
Resolving Power |
≥36dB |
Operating Temperature (℃) |
-20~50 |
|
Frequency Range(MHz) |
0.5 ~ 15 |
H×W×D(mm) |
240×156×48 |
|
Gain(dB) |
0 ~ 120 |
Weight(kg) |
1.0(with battery) |
|
Material Velocity(m/s) |
1000 ~ 15000 |
|
|
![]()
Standard Delivery:
Main unit
2.5MHZ-ф20 straight probe
4MHZ-8x9mm, 60degree angle probe
4A/9Vpower adapter
Probe connection cable (BNC to BNC)
Probe connection cable (BNC to Lemo 00)
Instruction manual
Carrying case
RS232-USB converter
Additional Accessories:
Data managing software
Data managing cables RS232
Straight probe (5MHZ-ф20)
Straight probe (2.5MHZ-ф20)
Straight probe (2.25MHZ-ф20)
Straight probe (1MHZ-ф20)
Angle probe (4MHZ-45degree, 8*9mm)
Angle probe (4MHZ-60degree, 8*9mm)
Angle probe (4MHZ-70degree, 8*9mm)
Angle probe (4MHZ-80degree, 8*9mm)
Angle probe (2MHZ-45degree, 8*9mm)
Angle probe (2MHZ-60degree, 8*9mm)
Angle probe (2MHZ-70degree, 8*9mm)
Angle probe (2MHZ-80degree, 8*9mm)
Probe T/R (5MHz-ф20mm, focus 15mm)
Probe T/R (2.5MHz-ф20mm, focus 15mm)
Connection cable to probe (BNC-BNC)
Connection cable to probe (BNC-Lemo 00)
Connection cable to probe (BNC-Lemo 01)
Connection cable to probe (Lemo 00-Lemo 01)
Lithium ion battery
Power adapter (4A/9V)
Power Cable
Leather case
|
Title |
FD510 |
FD520 |
FD550 |
|
Measuring Range |
0-6000mm |
0-10000mm |
0-10000mm |
|
Material Velocity(m/s) |
1000-15000 |
1000-15000 |
1000-15000 |
|
Gain(dB) |
110dB |
120dB |
130dB |
|
Frequency Range(MHz) |
0.5-15M |
0.5-15M |
0.5-20M |
|
Memory |
500 |
1000 |
1000 |
|
independence setup |
100 |
500 |
500 |
|
sz dB,ф |
★ |
★ |
★ |
|
Peak Hold and Peak Memory |
★ |
★ |
★ |
|
B scan |
X |
★ |
★ |
|
DAC |
★ |
★ |
★ |
|
AVG |
★ |
★ |
★ |
|
TCG |
X |
★ |
★ |
|
STANDARD(13 standards in-built) |
★ |
★ |
★ |
|
Automated calibration( IIW ) |
★ |
★ |
★ |
|
Automated calibration(two hole ) |
X |
X |
★ |
|
6dB DAC |
X |
★ |
★ |
|
make video |
★ |
unlimited |
unlimited |
|
pc software |
★ |
★ |
★ |
|
updated online |
★ |
★ |
★ |
|
curved surface correction |
★ |
★ |
★ |
|
AWS |
★ |
★ |
★ |
|
Pulse energy |
★ |
★ |
★ |
|
Pulse width |
★ |
★ |
★ |
|
Gate alarm |
★ |
★ |
★ |
|
DAC alarm |
★ |
★ |
★ |
|
continue working time |
9 hours |
12 hours |
12 hours |
|
Port Type |
BNC |
BNC |
BNC |
|
Overall dimension (mm) |
238×160×48 |
238×160×48 |
238×160×48 |
|
Weight (kg) |
1.0 |
1.0 |
1.0 |
Contact Person: Ms. Shifen Yuan
Tel: 8610 82921131,8618610328618