Product Details:
|
Storage Temperature: | -20 ~ 50 C | Working Temperature: | -10 ~ +40 C |
---|---|---|---|
Relative Humidity: | <80% Non Condensation | Work Temperature Rise: | <18 C |
Temporary Load Rate: | >50% | ||
High Light: | magnetic particle inspection equipment,magnetic particle test equipment |
Electromagnetic Yoke AC/DC Handy Magna Yoke Magnetic Flaw Detector HCDX-Y7
The HCDX-Y7 is a durable, AC/DC, BATTERY powered yoke designed to detect surface and sub-surface indications in the most rugged applications.
Featuring sealed chemical-resistant construction, articulating legs to contour to any part shape and robust strain-relieved twelve-foot cord for field use, the HCDX-Y7 is ideal for inspection of welds and other remote testing.
Solid-state controls allow the operator to use AC magnetic fields for surface indications or DC magnetic fields for sub-surface indications to meet all inspection needs.
Product features
Conform to JB/T7411-2012, ASME BPVC,ASTM E709,ASTM E1444,ASTM E3024
Solid Sealed, durable construction
Chemical and abrasion resistant
AC and DC operation options for surface and sub-surface inspection
Exceeds ASTM lifting specifications
There are places directly connected to AC power supply, which can be directly connected with AC power supply.
It is possible to use AC magnetized power supply (DC-AC inverter battery pack) to supply AC power without any direct insertion to AC power supply.
The DC magnetizing power supply (DC battery pack) can be used to realize the DC magnetization function.
The power display function can display the current battery power, and has the function of sound and light alarm.
Built in microcomputer chip to stabilize output voltage and ensure detection sensitivity.
Adjustable magnetization
Special working waist bag can carry battery pack, magnetic suspension, contrast agent, yoke probe, etc.
Model guide
HCDX-Y7
Electromagnetic Yoke | HCDX-Y7 |
Electrode spacing | 0~210mm |
Maximum current | 2.8A |
weight | 2.4kg |
major function |
Direct alternating current magnetization DC magnetization of rechargeable battery pack MT-500 |
Technical parameter
Working temperature: -10 ~ +40 C
Storage temperature: -20 ~ 50 C
Relative humidity: <80% non condensation
Work temperature rise: <18 C
Temporary load rate: >50%
Sensitivity: A1 standard test piece 15/50 groove clearly displayed.
AC minimum power hoisting power: >4.5kg (44N)
DC minimum power hoisting power: >18.1kg (177N)
Standard configuration:
HCDX-Y7
Magnetic powder flaw detector host 1
Power line 1
Rechargeable DC battery pack (DC magnetized power supply) 1
DC power backpack 1
Power adapter 1
DC output connection line 1
Instrument box 1
Defect examples: Defect location:
Inclusions Seams Surface and subsurface Ideal for: Fatigue cracks
Shrink cracks Tears Laps Field testing pot inspections
Welding slag Grinding cracks In-service inspections
Quenching cracks Demanding environments
Weld inspection
Contact Person: Ms. Shifen Yuan
Tel: 8610 82921131,8613910983110
Fax: 86-10-82916893