Product Details:
|
Scope Of Elemental Analysis:: | Sulfur (S) -Uranium (U) | Content Analysis Range:: | 1ppm~99.99% |
---|---|---|---|
Instrument Resolution:: | 145±5eV | Multichannel Analyzer:: | 2048 |
Test Time:: | 100 ~ 200 Seconds (time Can Be Adjusted According To Need) | Working Stability:: | The Total Fluorescence Intensity Was 0.1% |
Minimum Detection Limit:: | Cd/Cr/Hg/Br≤1ppm,Pb/Sb/Se/Ba≤2ppm,Cl≤5ppm | ||
Highlight: | RoHS XRF spectrometer,metal plating analyzer,halogen element XRF tester |
Attribute | Value |
---|---|
Scope of elemental analysis: | Sulfur (S) -Uranium (U) |
Content analysis range: | 1ppm~99.99% |
Instrument resolution: | 145±5eV |
Multichannel analyzer: | 2048 |
Test time: | 100 ~ 200 seconds (time can be adjusted according to need) |
Working stability: | The total fluorescence intensity was 0.1% |
Minimum detection limit: | Cd/Cr/Hg/Br≤1ppm,Pb/Sb/Se/Ba≤2ppm,Cl≤5ppm |
Type: | HXRF-360 |
---|---|
Scope of elemental analysis: | Sulfur (S) -Uranium (U) |
Scope of application: | European Union RoHS/ELV directive, halogen-free, eight heavy metals and metal material composition analysis |
Content analysis range: | 1ppm~99.99% |
Working stability: | The total fluorescence intensity was 0.1% |
Minimum detection limit: | Cd/Cr/Hg/Br≤1ppm,Pb/Sb/Se/Ba≤2ppm,Cl≤5ppm |
Instrument resolution: | 145±5eV |
Multichannel analyzer: | 2048 |
Working conditions: | Operating temperature: 15-30℃; Relative humidity: ≤80%; Power supply: AC :220V ±5V |
Appearance size: | 660mm×480mm×330mm |
Super-large measuring chamber: | 440mm×350mm×85mm |
Weight: | 60Kg |
Test time: | 100 ~ 200 seconds (time can be adjusted according to need) |
Configuration | Number | Unit |
---|---|---|
Instrument hardware part of the main configuration | ||
1. Imported high resolution electric refrigeration semiconductor detector | 1 | Set |
2. Imported ROHS+ halogen special X-ray tube | 1 | pc |
3. Imported high voltage power supply system | 1 | pc |
4. 2048 digital multichannel analyzer | 1 | Set |
5. High precision CCD | 1 | pc |
6. Filter automatic switching group | 5 | group |
7. Automatic switch of collimator: one collimator with diameter of 0.2, 0.5, 1, 2, 6 and 8mm | 6 | pc |
Instrument peripheral configuration | ||
1. Computer: Lenovo Business Computer | 1 | Set |
2. Canon color inkjet printer | 1 | set |
3. Silver correction sheet | 1 | pice |
4. Plastic standard sample: EC681M | 1 | pice |
5. Sample cup, Mylar membrane | A number of | |
The software configuration | ||
RoHS/halogen | 1 | Set |
Contact Person: Ms. Shifen Yuan
Tel: 8610 82921131,8613910983110
Fax: 86-10-82916893