Product Details:
|
Product Name: | Handheld Radiation Neutron Survey Meter | Uage: | Measuring Neutron Dose Equivalent (rate) |
---|---|---|---|
System Power Supplement: | DC 6V~24V | Neutron Energy: | 0.01μSv/h~100mSv/h |
Detector Fixing Type: | Wall Handling/in-built | Neutron Detector Type: | Li6 |
Highlight: | portable x-ray detector,weld x ray inspection machine |
Wall Handling And Handheld In Built Dosimeter 0.025eV~20MeV Radiation Neutron Survey Meter
HUATEC DL805-N Network Neutron radiation monitoring system mainly for radioactive workplace for online real-time monitoring of X-ray, gamma rays, and consists of a monitoring controller and multiple detectors. Between controller and detector uses the 485 industrial control bus communication connection can also be connected by wireless network communication. Real-time reflect the dose rate of each probe points.
Instrument characteristics
Controller uses a high-speed embedded microcontroller
processor, touch screen graphical dot-matrix liquid crystal
display and humanization Input, English status bar tip
operation, controller wall and desktop (optional)
Real-time sampling, data refresh quickly handle per second
Calendar and clock function
Outliers way of sound and light alarm set
Can be stored in excess of the alarm threshold and abnormal alarm record
Communications:
1,the standard RS485 interface, solve the similar communications equipment manufacturer unreliable, transmission distance is not long enough, communication problems in a wide range of cables
2,network communications, can realize the controller and detector, controller and a variety of wireless devices, controllers and the upper machine communication,
ZigBee mesh network of reliable and stable
3,GPRS or Internet to realize the global networking (optional)
4,video monitoring (cases)
Each detector alarm threshold can be set independently, at the same time with upper and lower limit alarm function. Built-in fault detection, dose rate, overload alarm and protection function, ensure the instruments work properly
Controller built-in sensors, can detect the controller around the ray intensity (optional)
Main technical indicators
Neutron energy range:0.01μSv/h~100mSv/h
Neutron detector type: Li6
Neutron energy response: 0.025eV~20MeV
Testing Ray type: n
Detector fixing type: Wall handling/in-built
Operating environment :temperature, -20℃~+60℃,relative humidity (under 40 ℃ temperature ) ≤98%
System power supplement:DC 6V~24V (The standard 12 v electric switch)
Standard Delivery
1. Main Unit
2. Manual
3. Calibration Certificate
4. Connect Cable
Accessories Delivery:
1. Li6 Neutron probe
Technical info
1,Measuring range: 0.01μSv/h~100mSv/h
2,Relative error: ≤10%
3,Energy response: 0.025eV~20MeV
4,Using environment: temperature: -20℃~+60℃, relative humidity: ≤98%( lower than 40℃)
5. power supply: DC 6V~24V
2. Gamma probe
Technical info
1,Measuring range: 0. 1μSv/h~30mSv/h, (can be expended upto 10sv/h)
2,Relative error: ≤10%
3. Sensitivity:≥350CPS/Sv/h
4,Energy response: 40Kev~3Mev
5,Using environment: temperature: -20℃~+60℃, relative humidity: ≤98%( lower than 40℃)
6. power supply: DC 6V~24V
Contact Person: Ms. Shifen Yuan
Tel: 8610 82921131,8613910983110
Fax: 86-10-82916893