Product Details:
|
Circumferential Magnetizing Current (AC):: | 0-3000A(virtual Value)adjustable Continuously, Phase Controlled Circuit Breaker | Vertical Magnetizing Current(AC): | 0-16000AT(virtual Value)adjustable Continuously, Phase Controlled Circuit Breaker |
---|---|---|---|
Magnezing Method: | Circumferential, Vertical,resultant Magnetization Coil Inner Diamter Φ500mm(one Piece) | Electrode Pole Distance:: | 0-1000mm Adjustable |
Clamp Travel Route:: | 40 Mm(single Phase) | Electrode Pole Rotating Speed:: | 10turns/minute |
Clamp Type: | Air Power Control Or Electric Control | Demagnezing Method:: | AC Attenuation Demagnezing |
Demagnezing Magnetomotive:: | AC 16000~0AT | ||
Highlight: | magnetic particle inspection equipment,mpi testing machine |
HCDX-3000SJ AC fluorescence magnetic test booth
Technical features
Magnetizing current:
Circumferential magnetizing current (AC): 0-3000A(virtual value)adjustable continuously, phase controlled circuit Breaker
Vertical magnetizing current(AC): 0-16000AT(virtual value)adjustable continuously, phase controlled circuit Breaker
Magnezing method: Circumferential, Vertical,resultant magnetization
Coil inner diamter Φ500mm(one piece)
Electrode Pole distance 0-1000mm adjustable
Clamp travel route 40 mm(single phase)
Electrode Pole rotating speed: 10turns/minute
Clamp type: Air power control or electric control
Demagnezing method AC attenuation demagnezing
Demagnezing magnetomotive: AC 16000~0AT
Remanence ≤0.2 mT
UV strength: ≥ 2000μW/cm2 (distance to UV light 380 mm)
Air power pressure: 0.4~0.8 Mpa (offered by customer)
Power: Three phase four line AC 380V 50Hz 150A
Outside size 1800(L)×800(W)×1900(H)
Total weight: about 1.0T
Duty cycle: ≥25%
Configuration
Model Configuration |
A | B | C |
PLC | ● | ● | ● |
Dial Ammeter | ● | ||
Digital Ammeter | ● | ||
Touch screen | ○ | ● | |
Current preset | ○ | ● | |
DC magnetizing | ○ | ○ | |
Contact inspection fuction | ○ | ○ | |
Anti spark cooper packing | ○ | ○ | ● |
Air power /electric clamp | ● | ● | ● |
AC magnetizing current | AC 2000A~6000A | ||
Max.distance of electrode pole | ≤3000mm | ||
Max.coil inner diameter | ≤700mm |
Note:“●” standard configuration,“○” optional
Contact Person: Ms. Shifen Yuan
Tel: 8610 82921131,8613910983110
Fax: 86-10-82916893