Product Details:
|
Max Penetration Thickness Steel (A3): | 40mm | Focal Distance: | 600mm |
---|---|---|---|
Exposure Time: | 5min | Darkroom Disposal: | 20±2℃ |
Highlight: | Radiation Portable X Ray Flaw Detector,Directional Portable X Ray Flaw Detector,GOST x ray flaw detector |
Directional radiation portable X-Ray Flaw Detector XXG-2505
List of the main parameters-XXG series
TYPE ITEM |
XXG2505 | ||
Max Penetration thickness Steel (A3) | 40mm | ||
Focal Distance | 600mm | ||
Exposure Time | 5min | ||
Film Type | TianJin Ⅲ | ||
Double lead foil Intensifying screen |
0.03 | ||
Darkroom Disposal | 20±2℃ | ||
Development | 5minutes | ||
Blackness | 1.5 | ||
Input | Voltage (V) | 220V±10% 50―60Hz | |
Capacity (KVA) | 2.5 | ||
Output | Tube voltage (KVP) | 50-200 | |
Tube current (mA) | 5 | ||
Stability | ±1% | ||
X-RAY Tube |
Focus mm2 | 1.0×20. | |
Radiation Angle | 40±5° | ||
Sensitivity | k≤1.8% | ||
Operation Mode | Intermittent operation, Radiating time to cooling time is 1:1 | ||
X-Ray Controller |
Dimension | 350×290×160 | |
Weight | 11kg | ||
Circuit Structure | Micro-computer control ,Modular structure,Voice prompt | ||
X-RAY Generator |
Cooling | Force air cooling | |
Insulation | SF6 Gas Insulation | ||
Working Pressure | 0.35Mpa-0.45Mpa | ||
Dimension | 320×320×650 | ||
Weight (kg) | 30.5kg | ||
Working Temperature | -10℃―+40℃ |
Features:
◆Adopting micro-computer control and modular structure,with strong anti-interference ability and high automaticity and reliable performance .
◆Parameter setting,working process and trouble indication will be indicated on the LED screen.
◆Independent aging key is designed for aging the machine conveniently.
◆Radiating time to cooling time is 1:1.
◆The controller can recognize the type of x-ray generator automatically.
◆The water and dust proof color panel and digital sound keyboard are introduced that exposure parameters are promptly and accurately selected.
◆Ensure safety using the instrument,it is installed with overvoltage,undervoltage,
overcurrent,undercurrent and overtemperature protection device.
◆A unique safety lock is designed that protect the operator from the damage of radiation.
◆Adopting the wider range of kv value, and solve the difficulty problem of short radiographic range.
◆Exposure delay function ------the delay time can be set less than 10 minutes to keep the operator safe from working place.
◆Match with various generator and function reliably.
◆Number of exposure can be accumulated.
(After the unit has been ready,but before press the "ON"key,you can press the "A" key (delay key) three times to check the number of exposure, and press any key to return back.)
◆With the outlet of ray warning lamp and wire connecting terminal of door-machine interlock.
(Door-machine interlock—when the lead door open ,the instrument cut off the high voltage automatically to protect the operator)
Standard Delivery:
DirectionalceramicX-ray tube | 1 Pcs | |
Generator | 1 Set | |
High voltage joins cable | 1 Pcs | 25 Meters |
Controller | 1 Set | |
Power cable | 1 Pcs | 10 Meters |
Grounding cable | 1 Pcs | 5 Meters |
Accessories | 1 Set | |
(Including: alarm lamp,1 Pcs; lead letter, 1 box; Film dark cassettes 5 pcs; intensifying screen 5 pcs; Wire penetrameter (IQI) 1 set; fuse1 pc |
Specification:
Output voltage (Kv) | Input (KW) | Focus spot (mm) | Beam angle | Max penetra tion (mm) | Weight (KG) | Dimensions (mm) | |||
XXG-250 5 | 150-250 | 2.5 | 2.0X2.0 | 40°+5 ° | 38 | Genera tor | Contr oller | Generator | Controller |
33.5 | 11 | 320x320x7 45 | 350x290x1 60 |
HUATEC has always been adhering to the first concept of customer-oriented, the products we sell will be carefully checked before shipping and then delivered to your hands.If you have any product requirements, you can contact me.Looking forward to your order.WeChat:19520504939
Contact Person: Ms. Shifen Yuan
Tel: 8610 82921131,8613910983110
Fax: 86-10-82916893