Product Details:
|
| Detector: | 4 Thin-film Plastic Scintillators + ZnS Coated Detector | Power Supply: | AC 220V (50/60H) |
|---|---|---|---|
| Alarm Methods: | Audible And Visual Alarms | Detection Efficiency: | α: Hands ≥35%, Feet ≥30%; β: Hands ≥40%, Feet ≥30% |
| Display: | 10-inch Touchscreen Color Display, Resolution 1024*600 | Measurement Areas: | Feet, Hands (palms And Backs Of Hands), And Forearms |
| Highlight: | High sensitivity nuclear pollution monitor,Alpha beta radiation detection device,Nuclear power plant radiation monitor |
||
FJ-HF11 High Sensitivity Nuclear Pollution Monitor Alpha Beta Radiation Detection for Nuclear Power Plant
This product is mainly used in nuclear power plants, nuclear facilities, and mining sites. It is used to measure the alpha and beta contamination on the hands, feet, and clothing surfaces of researchers and workers handling radioactive materials. When the alpha and beta radiation detected on the hands, feet, and clothing surfaces exceeds the threshold, the instrument will issue an alarm to ensure the personal safety of the staff and prevent internal radiation exposure.
Technical indicators
| Detector | 4 thin-film plastic scintillators + ZnS coated detector |
| Measurement type | α, β |
| Display | 10-inch touchscreen color display, resolution 1024*600 |
| Measurement areas | feet, hands (palms and backs of hands), and forearms. |
| Detection dimensions | 350mm × 200mm (foot), 250 × 180mm (hand) |
| Minimum detectable α activity |
≤0.037 Bq/cm2 (background <0.1 cps; 239 Pu) |
| Minimum detectable β activity | ≤0.37 Bq/cm2 (background <20 cps; 90 Sr- 90 Y) |
| Detection efficiency | α: Hands ≥35%, Feet ≥30%; β: Hands ≥40%, Feet ≥30% |
| Alarm methods | audible and visual alarms |
| Alarm Mode | Dynamic Alarm: Two-level alarm threshold settings: alarm coefficient and severity alarm coefficient. |
| Static alarms | Two-level alarm threshold settings: alarm threshold and critical alarm threshold |
| Alarm recovery | Alarm self-recovery can be freely configured according to usage requirements |
| High and low background alarm settings | After performing forced background measurement, high and low background alarm thresholds can be set according to the background conditions, based on the on-site usage environment |
| Equipment indicator lights | Real-time display of equipment status |
| Communication interface and hardware configuration requirements |
1 USB interface; 1 national standard power cord interface |
| Power suppl | AC 220V (50/60H) |
l Radionuclide laboratory;
l Nuclear fuel plant;
l Environmental surveying, national security;
l nuclear medicine;
l PET equipment.
l The 10-inch touchscreen color display makes it easy to operate.
l Intelligent operation with self-diagnosis function;
l The hand detector can be easily detached and used for measuring key areas of the body;
l The personnel location sensor can indicate the accurate location and provide voice prompts to guide the measurement.
l It uses a touch screen, allowing healthcare personnel to operate it independently, while the person being examined does not need to perform any operation, making it convenient to use;
l Radiation measurement parameter setting, status indication, and voice alarm functions;
l Local data storage, query, and dynamic display functions;
l It has a self-diagnostic function, and self-test items include: hand infrared detection and foot infrared detection;
l
When the measurement result is contaminated, a voice prompt, a text prompt, the location of the contamination, and the measurement result will be provided.
Environmental characteristics
l Temperature range: -10℃ ~ +40℃
l Relative humidity: ≤90% (35℃, non-condensing)
Mechanical properties
l Dimensions: 130 × 70 × 60cm
l Weight: 35kg
![]()
![]()
Contact Person: Ms. Shifen Yuan
Tel: 8610 82921131,8618610328618