Product Details:
|
Measuring Range: | 0~1250μm | Data Memory: | 500 Datas |
---|---|---|---|
Low Voltage Indication: | Indicator | Measuring Mode: | Continuous/single |
Shutdown Mode: | Manual/automatic | Weight: | 250g |
High Light: | coating thickness meter,digital coating thickness gauge |
Eddy current good stability 0.1um / 1um Coating Thickness Gauge TG8830N,1250 micron
TG8830N digital coating thickness gauge is using the non-magnetism measuring thickness method .It can measure the thickness of non-transmitting electricity cover layer (such as enamel, rubber, oil paint, plastic and etc) on the non-magnetism metal substrate (such as copper, aluminium, zinc, tin and etc) . This instrument has small error of measure, excellent performance and good stability, easy operation and other characteristics, is a necessary measure instrument to control and guarantee the product quality, can be widely applied to manufacturing, metal processing industry, chemical industry, merchandise test fields.
Features
Precise measurements (2%+1)/(1%+1)
Quick measuring response and rapid measuring speed
Design of two independent parts , better applicability, stable measurement results
Strong data processing and analysis :5 types of Statistic value and histogram
Technical Specification of Coating Thickness Gauge TG8830N
Measuring range |
N1:0~1250μm, |
|
Measuring accuracy |
1 point calibration : ±(2%+1)2 point calibration : ±(1%+1) |
|
Calibration |
1 point calibration /2 point calibration /basic calibration |
|
Display resolution |
0.1um (0~99.9um) / 1um (Over 100um) |
|
Weight |
250g(including battery package ) |
|
Operation environment |
Temperature: 0℃~50℃ humidity: 20%RH~90%RH |
|
Operation mode |
Direct testing mode and block statistics mode |
|
Measuring mode |
continuous/single |
|
Shutdown mode |
manual/automatic |
|
Operation alarm |
Ring music to alarm mistake |
|
Signal Dealing |
||
Threshold |
Limits setting and automatically alarm measured values out of limit |
|
Data analysis |
Analyzing a batch of measuring values via histogram |
|
Statistic function |
Mean/ Standard deviation / Number of measurements/ Maximum/ Minimum |
|
Data Merory |
||
Thickness values |
500 measuring data |
|
Delete |
Single doubtful data / All data of one group |
|
Power supply |
||
Battery |
9V Nickel-hydride/alkaline batteries |
|
Power battery inspection |
low voltage indication |
|
Standard delivery |
Main unit |
1 |
Integrated probe (N1) |
1 |
|
Calibration foil set |
4 |
|
Calibration base set |
1 |
|
9V alkaline battery |
1 |
|
Instruction manual |
1 |
Contact Person: Ms. Shifen Yuan
Tel: 8610 82921131,8613910983110
Fax: 86-10-82916893