Product Details:
|
Product Name: | Vibration Analyzer | Display: | 5-inch Color Display |
---|---|---|---|
Storage Space: | 16GB Hard Drive | Spectrum: | 1600、3200、6400 Or 12800 Lines FFT Spectrum |
Highlight: | 1600 Lines Vibration Analyzer,12800 Lines Vibration Analyzer,4 Channels Vibration Analyzer |
4 Or 2 Channels Vibration Analyzer 1600 3200 6400 12800 Lines FFT Spectrum
HUATEC HG-904A Four channel multi-functional instrument, features a versatile input port that can connect to various types of sensors. It utilizes advanced microelectronics, signal analysis, and fault diagnosis technologies, integrating equipment condition monitoring and fault diagnosis capabilities into a single unit.
The analyzer Instrument includes the function of four-channel vibration data acquisition, which can complete vibration measurement on-site and automatically store tens of thousands of vibration feature values and spectra of measurement points. It can also display one to four channels of waveforms and spectra synchronously on-site. Additionally, It can serve as an imbalance detector, completing single- and double-sided dynamic balance verification on-site.
BT4 &IP54
Please note:There is a big difference in hardware configuration between quad-channel and dual-channel.
Main function | Model | |
model | HG-904A4 | HG-904A2 |
Channel quantity | four channel | dual channel |
Main functions | ||
1,Three-channel synchronous inspection, with acceleration, velocity, displacement, and axis wrap-around values collected simultaneously from each channel, as well as frequency spectrum graphs of alarm parameters.
|
YES | 1 channel |
2,Single-channel or multi-channel synchronous acquisition of any parameter, any frequency range, and any graph. | 1 or 2 or 3 or 4 channel | 1 or 2 channel |
3,Axis trace, start-stop analysis, impact testing. | YES | NO |
4,Real-time monitoring of hardware values and real-time analysis of trend graphs for any parameter and any frequency range; real-time analysis of frequency spectrum and waveform. | 1 or 2 or 3 or 4 channel | 1 or 2 channel |
5,Rolling bearing impact pulse monitoring technology (judging bearing lubrication and impact) | Optional (Order notes) | Optional (Order notes) |
6,1 or 2 plane balancing | YES | YES |
7,Equipment management software analysis system | YES | YES |
8,Can be connected to ICP, charge sensor, eddy current displacement sensor, magnetoelectric speed sensor | YES | YES |
9,Relative phase analysis | Optional (Order notes) | Optional (Order notes) |
Main Function
Multifunctional Input Ports for Various Sensors: (Piezoelectric, Electromagnetic, Eddy Current, ICP)
-- 5-inch color display with Chinese interface for clear and beautiful visualization
-- Huge storage space with a 16GB hard drive that can automatically store tens of thousands of vibration feature values and spectra of measurement points
-- Four channels synchronous acquisition with 24-bit AD sampling
-- 1600,3200,6400 or 12800 lines FFT spectrum
-- USB 2.0 communication interface with a brand-new Chinese Window style menu display for easier operation
-- Analysis frequency up to 35 KHZ with 8 optional levels
-- Full-function high-speed dynamic analysis, including amplitude spectrum, power spectrum, logarithmic spectrum, etc.
-- Display various time domain feature values, including peak value, peak-peak value, effective value, peak factor, skewness, kurtosis, etc.
-- Multiple analysis and diagnosis functions: bearing/gear analysis (envelope demodulation analysis) fault diagnosis, (knock test) natural frequency diagnosis, etc.
-- Data/records storage and playback for rotor balance
-- Test weight can be selectively removed or retained and its quality can be estimated
-- High-precision balancing operation with quick balancing to measure and display vibration values, amplitudes, phases
-- Detection and diagnosis of bearing/gear faults using hardware envelope demodulation
-- Speed measurement, noise measurement, phase measurement, phase diagnosis
-- Manual setting of trigger threshold (large, medium, small)
-- It can be equipped with the EMD software of equipment management system (including bearing database)
Hardware specification
Stats | specification |
Model | HG-904A4 four channel / HG-904A2 dual channel |
Channel quantity | Four vibration channels, one tachometer channel |
Main functions | Single-channel or multi-channel synchronous acquisition of various parameters including acceleration, velocity, displacement, and axial envelope |
accuracy | ±5% |
A/D conversion | 24-bit AD sampling |
LCD display | Supports touch screen input, color 5-inch display |
Tachometer range | 120—12000rpm |
temperature range of instrument | -20—55°C |
temperature range of sensor | -20°—120°C |
Rechargeable battery | Rechargeable lithium battery 7.2V, 6800mA; charging time 7 hours, continuous working time 8 hours |
Charger | 8.V, 2A |
Diagnostic library | Bearing database |
Measurement function and range |
Simultaneously measures four parameter values and alarm parameter spectra with a sensitivity of 100 mv/g acceleration of 0.1——199.99 m/s² velocity of 0.1——199.99 mm/s displacement of 1um——1999um axial envelope value of 0.1——30 m/s² |
Software analysis function | Vibration spectrum and time domain waveform analysis, envelope analysis, precise fault diagnosis function for rolling bearings (four parts) Separate fault diagnosis function: The instrument hardware has a separate fault diagnosis function for collecting other parameter spectra, cepstrum, logarithmic spectrum, and power spectrum diagnosis (real-time acquisition and real-time display) |
Storage capacity | 16G |
External interface | Charging and communication USB2.0 |
Report output function | Detects data report output |
Vibration measurement frequency response range: | 2—35KHz |
Connectable sensor types: |
Piezoelectric acceleration sensor, ICP sensor, Magnetoelectric velocity sensor, Eddy current sensor
|
Hardware function interface
Main interface
Three-channel synchronous fast detection of multi-parameter values and alarm parameter spectrum
Multi-channel and multi-parameter real-time analysis
Multi-channel and multi-parameter real-time analysis
Software specification
1.The system requires simultaneous display of four parameters: acceleration, velocity, displacement, and axial envelope.
2.Trend charts for any parameter can be retrieved and viewed by time selection.
3.Single parameter trend chart, waveform chart, and frequency spectrum analysis chart can be displayed on the same interface.
4.Four parameter trend charts (acceleration, velocity, displacement, and axial envelope) can be displayed on the same interface.
5.Three parameter trend chart of acceleration, velocity, and temperature (including acceleration and velocity frequency spectrum analysis charts) can be displayed on the same interface.
6.Time domain analysis includes 13 sensitive fault diagnosis indicators.
7.Autocorrelation analysis function is available.
System Function Expansion Requirements:
8.Bearing residual life prediction reference.
9.Trend chart and frequency spectrum analysis should have self-diagnosis reference opinions.
10.Reports can be exported with one click.
11.Multi-parameter and multi-dimension diagnosis and analysis function is required.
System Operation and Maintenance Status Statistics:
12.Alarm status statistics are displayed.
13.Plan execution status is displayed.
System Operation and Maintenance Management:
14.Status of data collectors can be viewed.
15.Equipment status can be viewed.
One-click import of equipment inventory is available.
Contact Person: Ms. Shifen Yuan
Tel: 8610 82921131,8613910983110
Fax: 86-10-82916893