Product Details:
|
Name: | Vibration Calibrator | Frequency: | From 1 To 1280 Hz |
---|---|---|---|
Probe: | 5mm And 8mm Probes | Warranty: | 12 Months |
Highlight: | Vibration Calibrator Tester,Vibration Calibrator Tester Digital,Digital Vibration Calibrator Tester |
Digital Vibration Calibrator Tester Vibration Tester Calibration Vibration Calibrate HG5026
HG-5026 vibration calibrator can be used to calibrate vibration accelerometer, velocity and proximity transducer and also a vibration measuring instrument. Standard sine signal vibration at any frequency from 1 to 1280 Hz can be defined in the calibrator. The amplitude of the acceleration, velocity and displacement, can be defined through potentiometers and shown on digital displays. Either horizontal or vertical vibration can be generated. HG-5026 combines sine signal generator, power amplifier, standard transducer, vibration meter and a shaker in one and features a small volume, high accuracy and easy operation. It can be used either in laboratory or on site.
Wt
Freq |
<100g | <250g | <500g | ||||||
a(m/S2) | v(mm/S) | d(μm) | a(m/S2) | v(mm/S) | d(μm) | a(m/S2) | v(mm/S) | d(μm) | |
10Hz | 2.5 | 28 | 1300 | 3.5 | 40 | 1800 | 4 | 45 | 2000 |
20Hz | 15 | 85 | 1900 | 10 | 60 | 1300 | 5 | 28 | 640 |
40Hz | 60 | 170 | 2000 | 35 | 100 | 1100 | 12 | 35 | 380 |
80Hz | 100 | 141 | 800 | 40 | 60 | 320 | 14 | 20 | 110 |
160Hz | 75 | 53 | 150 | 35 | 25 | 70 | 12 | 8.5 | 24 |
320Hz | 50 | 18 | 25 | 30 | 10 | 15 | 10 | 3.5 | 5 |
640Hz | 30 | 5 | 3 | 20 | 3.5 | 2 | 6 | 1 | * |
1280Hz | 23 | 2 | * | 10 | 0.9 | * | 5 | 0.4 | * |
Frequency range & accuracy: 1 to 1280 Hz +0.01%
Contact Person: Ms. Shifen Yuan
Tel: 8610 82921131,8613910983110
Fax: 86-10-82916893