Product Details:
|
Display Error: | 0-199<2 Gu,200-2000<1% Gs | Test Accuracy: | <1%(Gs) |
---|---|---|---|
Measurement Spot: | 14×48(mm)ellipse | Dimension: | 114×35×65 (mm) |
Power Supply: | 1.5V AA Battery | ||
Highlight: | Paint Metal Mirror Gloss Meter,Accurate Metal Mirror Gloss Meter |
HGM-B60M Mini Metal Mirror Gloss Meter Paint Mirror Gloss Meter
Standard
International standard ISO2813, ISO7668, ASTM-D2457, DIN67530 and China standard GB9754, GB9966, GB8807.
The technical parameters follows China metrology standard JJG696-2002.
Application
HGM-B60M type ( metal ) gloss meter is follow the is0-2813 iS0-7668 GB8807 standard manufacturing precision. Mini gloss meter suitable for metal mirror gloss measurement .
HUATEC Gloss meter Reference angle for different application
Angle | Point of reference for (foreign) (China) |
Application
|
20° |
DIN-67530 ISO-2813 GB9754 ASTM-D523 ASTM-D2457 GB8807 |
high gloss paint, ink, plastic. |
20° |
ASTM-D1834 TAPPI-T653 GB8941.1 |
high gloss stencil, cast coated paper. |
45° |
ISO-2767 GB8941-2 | surface of aluminum and aluminum oxide. |
45° |
ASTM-C346 GB/T3295 ASTM-D2457 GB8807 |
pottery, ceramic, plastic, plastic film, Stone |
45° | JIS-E8741 | pottery, ceramic, plastic, plastic film, Stone |
60° |
ISO-2813 GB9754 ASTM-C584 GB9966 ASTM-D523 DIN-67530 ASTM-D2457 GB8807 |
Mid-gloss paint, ink, plastics, ceramics, stone.
|
75° |
ISO-8254 TAPPI-T480 GB8941.3 |
copperplate paper |
85° |
ISO-2813 GB9754 DIN-67530 ASTM-D523 |
high gloss paint, ink, plastic. |
Features
1. Small and light, real easy to be carried and used.
2. One 1.5 mignon alkaline Battery can be used for almost 60 hours and 10000 reading.
3. High stability
4. Long-term stable light source needs no replacing forever.
5. Quartz crystal standard board, no excursion.
6. Zero self-adjustment.
Parameter
The technical parameters up to JJG 696 (First-level standard).
1, test swpe:0.0-1999.0(Gs)
2, test accuracy:<1%(Gs)
3, stability:2Gs/30min
4, test caliber:14×28(mm) ellipse
5, size:114×35×65 (mm)
6, power:1.5V AA battery
Instructions
1. Switching meter to open, press the need to test the key point.
2. Operation: Open standards board boxes, and glass will be standard for on-board flat on the table, will center positioning meter, "inverted triangle" signs at the edge groove center, adjust adjustment knobs, meter readings should be the same to the standard black glass plate nominal value (see box corresponding standard plate angle data).
3. Calibration: measuring equipment calibration good white ceramic plate (to be positioning equipment centers "inverted triangle" signs at the edge groove Centre) the corresponding numerical point of the show should not be larger than the standard white ceramic plate nominal value ± 1.2 gloss units, or black and white standards board should check the cleanliness of the surface, or equipment failure. If meter is working well, do not need to make calibration as often.
4. Measurement: Use the good calibration meter to measure the tested samples.
Standard Delivery
Gloss meter | 1pc |
Instrument case | 1pc |
Standard board |
2pc A black board is used for the highlight calibration A white board is used for the low light calibration |
English instruction manual | 1pc |
Calibration certificate | 1pc |
Contact Person: Ms. Shifen Yuan
Tel: 8610 82921131,8613910983110
Fax: 86-10-82916893