| Frequency Range: | 10Hz~15MHz | Gain Adjustment Range: | 0~90dB,Minimum Step 0.5 DB |
|---|---|---|---|
| Number Of Channels: | 64 Channel | Digital Filtering: | 1~100 |
| Front Gain: | 10~35dB | High-pass Filtering: | 0~500Hz |
| Low-pass Filtering: | 10Hz~10KHz | Amplitude And Phase Measurement: | Automatic/Manual |
| Highlight: | Multi-frequency eddy current testing equipment,Aerospace NDT testing equipment,Petrochemical eddy current tester |
||
HEF-2501 Multi-Frequency Array Eddy Current Testing Equipment for Aerospace & Petrochemical
HEF-2501 array eddy current detector is an array multi-frequency eddy current detector. It can detect defects in metal materials in real time and effectively, distinguish alloy types, heat treatment states and thickness changes, etc. The test results obtained by combining multiple detection methods can facilitate the comprehensive data analysis and mutual verification by the inspectors, thereby obtaining a more objective and true evaluation. It is particularly applicable to pre-service and in-service non-destructive testing in fields such as aviation, aerospace, power, nuclear engineering, metallurgy, shipping, petrochemicals, and automobiles.
I. Function Description
• 64-channel array eddy current testing
• Non-directional weld seam inspection
• Unique crack depth detection function;
• Impedance planar diagram, time base scanning diagram display, time base superimposed display, array eddy current scanning II (B/C), and three-dimensional imaging display functions;
• High definition and high sensitivity;
• Simple operation, with both Chinese and English operation interfaces (optional);
• The data acquisition of the C-scan view can quickly and effectively detect defects and locate them.
• Supports measurement of pipe wall thickness thinning, surface defect detection and depth measurement, measurement of thickness of surface coatings and plating layers of metal materials, and sorting of various metal materials and hardness.
• It has 32 comprehensive processing (mixing) units: capable of simultaneously separating or suppressing multiple groups of interference signals;
• Multiple filtering methods
• Diverse data storage methods
• It has the function of multi-frequency detection configuration analysis
• It stores detection parameters and data, and can export reports in PDF, EXCEL, WORD, etc
• It can store/reproduce the signal waveform of the entire detection process
• It is equipped with a built-in lithium battery and can work continuously for more than 6 hours
二,Performance index
|
Item |
Performance index |
|
Number of links |
2pcs |
|
Number of channels |
64 Channel |
|
Probe interface type |
LEMO Interface |
|
Frequency |
4 |
|
Frequency range |
10Hz~15MHz |
|
Gain adjustment range |
0~90dB,Minimum step 0.5 dB |
|
Impedance plane |
32pcs |
|
Automatic mixing unit |
32pcs |
|
High-pass filtering |
0~500Hz |
|
Low-pass filtering |
10Hz~10KHz |
|
Digital filtering |
1~100 |
|
Front gain |
10~35dB |
|
Drive |
Level 8 |
|
Amplitude and phase measurement |
Automatic/Manual |
|
Layout display |
Impedance planar diagram, time base scanning curve display, A-scan display |
|
Alarm mode |
Half-phase alarm/phase alarm/box alarm |
|
Alarm output signal |
Transistor OC gate output |
|
Balance mode |
Digital electronic balance |
|
Filtering method |
three types: high-pass, low-pass and digital filtering |
|
Display mode |
Point/line/fading can display the maximum crack depth and show the crack depth in real time |
|
Probe calibration |
It has the function of displaying the waveform of the fundamental frequency signal before detection with scale marks. It has the function of sensor self-diagnosis |
|
Bidirectional gain ratio(Y/X) |
0.1 to 10/0.1 to 10, where X and Y can be set separately |
|
Calibration curve |
Defect depth (thickness) - amplitude /Y amplitude/phase curve calibration function |
|
Extended function |
Replay, analyze and save the eddy current detection signal |
|
Data analysis |
Automatically generate inspection reports, including inspection information, defect signals, location, date, personnel and other inspection parameters |
|
Data recording and management |
1.The system can save the impedance time base diagram of local defect signals, the waveform file of defect signals, and the corresponding parameter configuration during testing. 2. The system can save and replay the data of each detection waveform in real time, and analyze the saved signal waveforms. 3. The system is equipped with a memory card, which can bring the on-site detection data back to the laboratory for analysis, facilitating storage. |
|
Human-computer interaction |
The system can manually separate and classify signals to obtain characteristic parameters such as amplitude and phase of different types of signals. 2. The system can manually revise the phase offset of different signals. 3. The system has the function of calibrating the amplitude of the standard sample signal. 4. The system can set the duration of data collection. |
|
Size, weight |
292×214×69mm; 2.7 kg |
|
Working temperature range |
-20℃ ~ +55℃ |
|
External power supply |
Adapter: DC19V, rechargeable lithium battery (14.8V 5.7AH) |
三,Configuration list
|
SN. |
Name |
Model specification |
Quantity |
Unit |
Remarks |
|
1 |
Array eddy current detector |
HEF-2501 |
1 |
pc |
|
|
2 |
laptop |
D e l l |
1 |
pc |
|
|
3 |
32-channel array probe |
Customized |
1 |
pc |
Directionless detection probe |
|
4 |
Pen-type probe |
EPB2.JO.20 |
1 |
pc |
|
|
5 |
Curved pen-type probe |
EPB2W.JO.20 |
1 |
pc |
|
|
6 |
Edge probe |
EPD1.CO.10 |
1 |
pc |
|
|
7 |
Array test block |
Stainless steel |
1 |
pc |
|
|
8 |
Compare the test blocks |
steel |
1 |
pc |
|
|
9 |
Array eddy current adapter wire |
LEMO16 core -LEMO19 core |
1 |
pc |
|
|
10 |
Communication line |
Network cable |
1 |
pc |
Super Category 5 |
|
11 |
Power adapter |
DC-19V |
1 |
pc |
|
|
12 |
Instrument box |
|
1 |
pc |
|
|
13 |
Product Qualification Certificate |
|
1 |
pc |
|
|
14 |
Quality Guarantee Certificate |
|
1 |
pc |
|
|
15 |
Quality Feedback form |
|
1 |
pc |
|
|
16 |
Instrument Operation Guide |
|
1 |
pc |
|
|
17 |
System software backup |
English/USB flash drive |
1 |
pc |
|
![]()
Contact Person: Ms. Shifen Yuan
Tel: 8610 82921131,8618610328618
Fax: 86-10-82916893