Product Details:
|
Measuring Range: | Dose Rate:0.01 µSv/h ~30mSv/h Cumulate Dose:0.00 µSv ~999.9mSv | Energy Range: | 40Kev~1.5Mev |
---|---|---|---|
Energy Response Error: | ≤±30%(according To 137Cs) | Relative Basic Error: | ≤±10% |
Alarm Value: | 0.5、1.0、2.5、10、30、50、100、500 µSv/h | Protective Alarm Response Time: | ≤5 Second |
Highlight: | Radiation Meter,Radiation Dose Alarm Meter,Dose Alarm Meter |
DP802i X-γ Ray Radiation Personal Dose Alarm Meter
DP802i X-γ Radiation Personal Dose Equivalent (rate) Monitor is mainly used for gamma rays, X rays and hard beta radiation protection monitoring, suitable for nuclear power plant, the accelerator, isotope applications, industrial X-ray, gamma NDT, radiation therapy, cobalt gamma irradiation, radioactive laboratory, nuclear facilities around the environmental monitoring field, timely alarm indicator, ensure the safety of workers, The instrument can be measured simultaneously dose rate and cumulative dose.
It adopts new chip technology, low power consumption, the detector is compensative GM count, wide measuring range, good energy response characteristics, and fault detection, dose rate overload alarm and protection function.
Main specifications:
Types of measured Ray | X, γ and hard-β rays |
Measuring range |
dose rate:0.01 µSv/h ~30mSv/h Cumulate dose:0.00 µSv ~999.9mSv |
Energy range | 40Kev~1.5Mev |
Energy response error |
≤±30%(according to 137Cs) |
Relative basic error |
≤±10% |
Measuring time |
automatic adjustment according to radiation, quick response |
Alarm value | 0.5,1.0,2.5,10,30,50,100,500 µSv/h |
Protective alarm response time |
≤5 second |
Display |
LCD |
Display unit | dose rate (µSv/h or mSv/h) and Cumulate dose (µSv or mSV) |
Power | AAA battery 1pc,15 days working time |
Size |
90*60*17 (mm) |
Weight | 80g |
Purpose of use:
Measurement of personal gamma and X-ray radiation equivalent dose rate(EDR)
Measurement of personal gamma and X-ray radiation equivalent dose(ED)
Alarm of exceeded programmed threshold levels
Application:
Nuclear facilities around environmental radiation detection
The soil surface radiation pollution detection
Agricultural radiation pollution detection
Ore, building materials radioactive detection
Personal dose monitoring alarm
Industrial X, gamma NDT radiation detection
Radiation medical treatment place radiation detection
Cobalt source, electronic accelerator irradiation place radiation detection
Radioactive radiation laboratory detection
Standard Delivery:
Name | QTY. | Unit | |
DP802i main body | 1 | set | |
Calibration certificate | 1 | pc | |
Instruction Manual | 1 | PC |
Contact Person: Ms. Shifen Yuan
Tel: 8610 82921131,8613910983110
Fax: 86-10-82916893