logo
Home ProductsNon Destructive Testing Equipment

MTU-3 MPI Reference Block Type 1

Certification
China HUATEC  GROUP  CORPORATION certification
China HUATEC  GROUP  CORPORATION certification
Customer Reviews
wide range of NDT products, we can get all in huatec group. We prefer to buy from them. Rudolf Shteinman Russia

—— Rudolf Shteinman

I like the service, very quick response, professional work. Aret Turkey

—— Aret Kaya

huatec hardness tester, very good quality,we are very satisfied with the portable hardness tester RHL-50. Kumaren Govender Sotuth Africa

—— Kumaren Govender

I'm Online Chat Now

MTU-3 MPI Reference Block Type 1

MTU-3 MPI Reference Block Type 1
MTU-3 MPI Reference Block Type 1 MTU-3 MPI Reference Block Type 1 MTU-3 MPI Reference Block Type 1

Large Image :  MTU-3 MPI Reference Block Type 1

Product Details:
Place of Origin: China
Brand Name: HUATEC
Certification: EN ISO 9934-2:2002
Model Number: MTU-3
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: carton
Delivery Time: 5-8 working days
Payment Terms: T/T,Western Union

MTU-3 MPI Reference Block Type 1

Description
Name: MTU-3 MPI Reference Block Type 1 Application: Fluorescent MPI Reference Block
Keywords: MTU-3 MPI Reference Block Type 1 Use: Magnetic Particle Suspension Verification Block
Highlight:

MPI reference block Type 1

,

Non-destructive testing calibration block

,

MTU-3 MPI standard test block

MTU-3 MPI Reference Block Type 1

EN ISO 9934-2:2002

MTU-3 MPI Reference Block Type 1 (also known as MTU Test Block No. 3) is a wet sensitivity calibration standard block for magnetic particle inspection (MPI), used to verify the detection capability and system status of magnetic suspensions/powders. It is the core quality control tool for non-destructive testing (NDT).

Core functionality
Sensitivity verification: Verify the defect display ability of magnetic powder/magnetic suspension, and determine whether the sensitivity has decreased due to aging or contamination.
System quality control: Daily/regular verification of MPI equipment, magnetic suspension concentration, and lighting conditions (UV/white light) to ensure compliance.
Benchmark comparison: Comes with a standard reference image, which compares the measured crack display with the benchmark to determine whether the system is qualified.
Consumables evaluation: Compare the testing performance of different brands/batches of magnetic powder and new and old magnetic suspensions.

MTU-3 MPI Reference Block Type 1 usage and functional analysis

1. Verify the magnetization effect (magnetic field direction and intensity)

MTU-3 test blocks are usually made of materials with high magnetic permeability, When the test block is placed on the surface of the inspected workpiece and magnetized together with the workpiece, The operator determines the direction of the magnetic field on the surface of the workpiece by observing which directions of defects display magnetic traces. For example, if only radial cracks are visible, it indicates that the magnetic field is circumferential; If only concentric cracks are displayed, it indicates that the magnetic field is radial.

2. Evaluate the comprehensive sensitivity of the system

The artificial defects on the test block are very subtle and can only be clearly displayed when the entire detection system (current value, magnetization method, magnetic suspension concentration, cleanliness, lighting conditions, etc.) is in good condition.

3. Daily performance verification

·Before starting the testing work every day, or after replacing the testing process and equipment, using MTU-3 test blocks for a quick calibration is an important quality control step to ensure the reliability of the testing results. This meets the regulatory requirements of high standard industries such as aerospace, nuclear power, and pressure equipment.

4. Compare the performance of different magnetic suspensions

·By using the same MTU-3 test block and the same magnetization specification, the performance of magnetic suspensions (including fluorescent and non fluorescent) from different batches or suppliers can be compared. A better performing magnetic suspension will result in clearer defect display and higher contrast on the test block.

During the magnetic particle testing process, the MTU-3 Type I test block quickly and intuitively verifies and confirms whether the comprehensive sensitivity of the entire testing system (including equipment, magnetization method, magnetic suspension performance, and operating process) meets the required standards, and displays the direction of the magnetic field on the workpiece surface.

The MTU-3 MPI Reference Block Type 1 is a key tool for ensuring the reliability, consistency, and traceability of magnetic particle testing results.

MTU-3 MPI Reference Block Type 1


MTU-3 MPI Reference Block Type 1 0



Contact Details
HUATEC GROUP CORPORATION

Contact Person: Ms. Shifen Yuan

Tel: 8610 82921131,8618610328618

Fax: 86-10-82916893

Send your inquiry directly to us (0 / 3000)